Page 69
Integrated Modules
Integrated Modules
Troubleshooting
4-8
#826498 - Revision B - December, 2016
22
30
31
36
39
47
U400
Pad Error
Data Flash Error
(result of flashing software)
Invalid Configuration
TC temperature too high
Controller Options Error
LIN Communication Error
Over Voltage
None
None
None
Control Temperature Readout
None
None
1. Test L1 to Ground
2. Test L2 to Ground
3. Test L1 to L2
1. Cycle unit power.
2. Reseat LV Wire Harness -
CE
.
3. Reseat comm cable -
CI and TM
.
4. Perform unit reconfiguration.
5. Replace control board.
1. Cycle unit power.
2. Perform unit reconfiguration
3. Replace control board.
1. Not valid on
CE152TF/S
.
CI152TF/S and TM15TF/S
1. Perform unit reconfiguration.
2. Replace generator.
1. Not valid on
CE152TF/S
.
CI152TF/S and TM15TF/S
1. Test fan operation.
2. Ensure fan vent is not blocked.
3. No large pot or pan overlapping
the control area.
4. Direct sunlight or heat lamps not
shinning on controls.
5. Replace control board.
1. Cycle unit power.
2. Inspect and reseat LV wire
harness -
CE
.
3. Inspect and reseat comm cable -
CI and TM.
4. Perform unit reconfiguration.
5. Replace control board.
1. Inspect control board.
2. Inspect and reseat LV wire
harness -
CE
.
3. Inspect, reroute, and reseat
comm cable -
CI and TM
4. Perform unit reconfiguration
5. Replace comm cable-
CI and TM
6. Replace control board.
1. L1 to Ground and L2 to Ground
≤ 132 VAC.
2. L1 to L2 ≤ 265 VAC
3. Confirm single phase circuit.
4. If electrical problem report issue
to consumer.
5. If no issue found replace power
board -
CE
.
6. If no issue found replace gener-
ator -
CI and TM.
General Errors Table - CE152TF/S, CI152TF/S and TM15TF/S
Code
Description
Test
Action