Page 39
Component Removal
Integrated Modules
Integrated Modules
3-7
#826498 - Revision B - December, 2016
Coil Assembly
To remove the coil assembly, first remove the glass top,
then (See Figure 3-9):
1.
Use a small flat blade screw driver to lift the coil
assembly from the wire side of the coil assembly.
2.
Lift coil assembly off hook and loop fastener tab
opposite the wire side of the coil assembly.
3.
Use a T-25, a large phillips screw driver, or a large
flat blade screw driver to loosen screws holding coil
assembly wires.
4.
Disconnect Negative Temperature Coefficient (NTC)
sensor cable from below generator plate.
5.
Remove coil assembly.
Note:
Coil assembly wires are covered by insulation.
The black insulation is on the solid black wire
and should be connected to the coil assembly
terminal nearest the front.
Generator Plate
To remove the generator plate, first disconnect the com-
munication (comm) harness and remove the coil
assemblies, then (See Figure 3-10):
1.
Use a phillips screw driver to extract ground
screw.
2.
Use a T-15 to extract screws holding the generator
plate to the generator.
3.
Feed comm harness through generator plate.
4.
Remove generator plate.
Figure 3-9. Coil Assemblies
Figure 3-10. Generator Plate
Ground Screw
T-15 Screw
Generator
Plate
Insulation