Page 71
Integrated Modules
Integrated Modules
Troubleshooting
4-10
#826498 - Revision B - December, 2016
E00
E01
E02
E03
E04
E05
E06
E07
E08
E09
E10
NO_ERROR
APPLIANCE_TYPE
RTD_LIQUID_OPEN
RTD_LIQUID_SHORTED
RTD_PAN_OPEN
RTD_PAN_SHORTED
RTD_CIRCUIT
THERMISTOR_AMBIENT_
OPEN
THERMISTOR_AMBIENT_
SHORTED
AMBIENT_TEMP_TOO_HIGH
DRY_START
No Error
Appliance type is not valid
Main RTD is open
(Main RTD exceeds 1000° F
for 20 seconds in any mode)
Main RTD is shorted
(Main RTD exceeds -50° F for
20 seconds in any mode)
RTD Steam Fill Sensor is open
(RTD Steam Fill exceeds 1000°
F for 20 seconds in any mode)
RTD Steam Fill is shorted
(RTD Steam Fill exceeds -50°
F for 20 seconds in any mode)
Main RTD/RTD Steam Fill
sensing circuit error
Calibration error.
•
Reference port pin ground-
•
ed
RTD port pins shorted.
•
Ambient thermistor on
power board is open
Ambient thermistor on power
board is shorted
Ambient temperature above
limit
(limit setable from 176°F
to 221°F. Default is 217°F)
Dry Start at startup
SM15TF/S: RTD Steam Fill
•
is 18°F more than Main
RTD during the first 90
seconds.
FM15TF/S: RTD Steam Fill
•
is 30°F more than Main
RTD during the first 120
seconds.
No action required.
1. Unit will try to reset and if appli-
ance type can’t be determined,
unit will default to steamer.
2. Replace module power board.
1. Check resistance of Main RTD.
2. Replace Main RTD.
3. Replace module power board.
1. Check resistance of Main RTD.
2. Replace Main RTD.
3. Replace module power board.
1. Check resistance of RTD Steam
Fill Sensor.
2. Replace RTD Steam Fill Sensor.
3. Replace module power board.
1. Check resistance of RTD Steam
Fill Sensor.
2. Replace RTD Steam Fill Sensor.
3. Replace module power board.
1. Check resistance of both RTDs.
2. Replace module power board.
1. Cycle power to the unit.
2. Replace module power board.
1. Cycle power to the unit.
2. Replace module power board.
1. Cycle power to the unit.
2. Replace module power board.
1. Clean debris/build-up from bot-
tom interior of pan.
2. Add liquid to the pan.
General Errors - SM15TF/S, FM15TF/S, and GM15TF/S
Code
Software Designator
Description
Action