POWER AND GAS REQUIREMENTS:
CE152TF/S and CI152TF/S
Power Rating and Electrical Service:
180 VAC to 265 VAC, single phase, 60 Hz, dedicated circuit.
CE152TF/S - Cooktop Electric 3.4 kW at 240 VAC
Breaker - 20 Amp dedicated circuit
2.9 kW at 208 VAC
CI152TF/S - Cooktop Induction 3.7 kW at 240 VAC
Breaker - 20 Amp dedicated circuit
3.2 kW at 208 VAC
CG152TF/S and MM15TF/S
Power Rating and Electrical Service:
CG152TF/S - Cooktop Gas
120 VAC
Breaker - 15 Amp dedicated circuit
MM15TF/S - Multifunction Module 120 VAC
Breaker - 15 Amp dedicated circuit
Gas Supply Requirements:
Natural Gas:
Minimum Supply Line Pressure - 7” WC
Maximum Supply Line Pressure - 14” WC
Regulated Manifold Pressure - 5” WC
LP Gas:
Minimum Supply Line Pressure - 11” WC
Maximum Supply Line Pressure - 14” WC
Regulated Manifold Pressure - 10” WC
SM15TF/S, FM15TF/S, and GM15TF/S
Power Rating and Electrical Service:
180 VAC to 265 VAC, single phase, 50/60 Hz, dedicated circuit.
SM15TF/S - Steamer Module
2.7 kW at 240 VAC
Breaker - 15 Amp dedicated circuit
2.0 kW at 208 VAC
FM15TF/S - Fryer Module
2.7 kW at 240 VAC
Breaker - 15 Amp dedicated circuit
2.0 kW at 208 VAC
GM15TF/S - Grill Module
2.8 kW at 240 VAC
Breaker - 15 Amp dedicated circuit
2.1 kW at 208 VAC