Page 23
Electronics and Gas Theory
Integrated Modules
Integrated Modules
2-13
#826498 - Revision B - December, 2016
b.
Power Level Readout - SM15TF/S, FM15TF/S and GM15TF/S
Touch
“+”
pad during the LED test.
1.
Two
“.”
are displayed on rear control zone.
2.
Touching the front or rear control zone indicates the power level in the temperature display.
3.
LO
displays the power level of 0.
4.
HI
displays the power level of 255.
5.
“-”
pad engages LED Test and
“+”
pad engages Control Temperature Readout.
6.
c.
Control Temperature Readout - CE152TF/S, CI152TF/S, and TM15TF/S
Touch
“+”
pad during Unit Reconfiguration.
1.
CE152TF/S
and
CI152TF/S
- three
“.”
are displayed on rear control zone.
•
TM15TF/S
- three
“.”
are displayed on front control zone.
•
2-digit display shows the ambient control temperature in °C.
•
Over 99° C (210° F), the decimal point of the 2 digit display turns on to indicate the temperature is
•
100° C or higher.
“-”
pad returns to Unit Reconfiguration and
“+”
pad advances to Heat Sink Temperature.
2.
c.
Control Temperature Readout - SM15TF/S, FM15TF/S, and GM15TF/S
Touch
“+”
pad during Power Level Readout.
1.
Three
“.”
are displayed on rear control zone.
•
The temperature display shows the ambient control temperature in °C.
•
“-”
pad returns to Power Level Readout and
“+”
pad advances to Heat Sink Temperature.
2.
d.
Heat Sink Temperature Test - CE152TF/S
Touch
“+”
pad during the Control Temperature Readout.
1.
Four
“.”
are displayed on the left rear control zone.
•
2-digit display shows 00. There is no state on the CE152TF/S.
•
“-” pad returns to Control Temperature Readout and “+” pad advances to Coil Temperature test.
2.
d.
Heat Sink Temperature Test - CI152TF/S
Touch
“+”
pad during Control Temperature Readout.
1.
Four
“.”
are displayed on the left rear control zone.
•
2-digit display shows the current heat sink state.
•
“0”
- temperature is ≤ 176° F - unit works correctly.
•
“1”
- temperature is > 176° F - boost is disabled for affected zone.
•
“2”
- temperature is > 192° F and ≤ 201° F - zone limited to 60% power.
•
temperature is > 201° F and ≤ 210° F - zone limited to 40% power.
•
“3”
- temperature is > 210° F - zone turns off.
•
“-”
pad returns to Control Temperature Readout and
“+”
pad advances to Coil Temperature test.
2.
d.
Heat Sink Temperature Test - TM15TF/S
Touch
“+”
pad during Control Temperature Readout.
1.
Four
“.”
are displayed on the front control zone.
•
2-digit display shows the current heat sink state.
•
“0”
- temperature is ≤ 176° F - unit works correctly.
•
“1”
- temperature is > 176° F - unit works correctly (no boost).
•
“2”
- temperature is > 192° F and ≤ 201° F - zone limited to 60% power.
•
temperature is > 201° F and ≤ 210° F - zones limited to 40% power.
•
“3”
- temperature is > 210° F - zone turns off.
•
“-”
pad returns to Control Temperature Readout and
“+”
pad advances to Coil Temperature test.
2.