Page 66
Troubleshooting
Integrated Modules
Integrated Modules
4-5
#826498 - Revision B - December, 2016
Heat Sink Performance notes - CI152TF/S
Touch the front control zone
SIM/MLT
or
HI
pad cycles through the heat sink temperatures.
1
Front control zone
SIM/MLT
and
HI
LEDS are on.
•
Front control zone displays dimmed 1, 2, or 3
“.”
to indicate heat sink number, with one
“.”
on to
•
indicate which heat sink temperature is displayed.
First LED is generator board #1.
•
d.
RTD Temperature Test - SM15TF/S, FM15TF/S, and GM15TF/S
GM15TF/S
- No RTD - 2 digit display shows
“--”
and temperature display is blank.
•
Touch
“+”
pad during the Control Temperature Readout.
1
Four
“.”
are displayed on the rear control zone.
•
Touch of front control
HI
will toggle to the next RTD in sequence.
•
Touch of front control
LO
will toggle to the previous RTD in sequence.
•
The timer display will show
“LI”
when the Main RTD temperature is displayed.
•
The timer display will show
“PA”
when the RTD Steamer Fill Sensor temperature is displayed.
•
“-” pad returns to Control Temperature Readout and “+” pad advances to error code indicator.
2
e.
Coil Temperature Test - CI152TF/S and TM15TF/S
CE152TF/S
- This mode is present but shows 00 as it is not active.
•
Touch
“+”
pad during the Heat Sink Temperature test.
1
Five
“.”
are displayed on rear control zone.
•
2-digit display shows the coil temperature in °C.
•
Over 99° C (210° F), the decimal point of the 2 digit display turns on to indicate the temperature is
•
100° C (210° F) or higher.
CI152TF/S
front
SIM/MLT
and
HI
are on. Touch the front control zone
SIM/MLT
or
HI
pad cycles
2
through the coil temperatures.
Front control zone displays dimmed 1, or 2
“.”
to indicate coil number, with one
“.”
on to indicate
•
which coil temperature is displayed.
• First LED is coil assembly and NTC #1
• Second LED is coil assembly and NTC #2
TM15TF/S
rear
LO
and
HI
pad cycles through the coil temperatures
3
Front control zone displays one or two
“.”
to indicate which coil temperature is being displayed.
•
First LED is coil #1
•
Second LED is coil #2
•
“-”
pad returns to Heat Sink Temperature Test and
“+”
pad advances to Error Code Indicator.
•
Coil Temperature Performance Impact - CI152TF/S
160° C (320° F) boost is disabled for affected zones.
•
240° C (464° F) affected zones are limited to 60% power.
•
260° C (500° F) affected zones are turned off.
•
285° C (545° F) all zones are turned off.
•