Page 57
Component Removal
Integrated Modules
Integrated Modules
3-25
#826498 - Revision B - December, 2016
Figure 3-49. FM15 RTD Steamer Fill Sensor
Steamer Fill Sensor RTD
To remove the steamer fill sensor RTD, first remove the
rear access panel, then (See Figure 3-49):
Use a 5/16” open end wrench or nut driver to
1.
extract the nut from the pan stud.
Remove the front access panel.
2.
Disconnect the steamer fill sensor RTD from the
3.
module power board.
Remove the steamer fill sensor RTD.
4.
Pan Assembly Steamer, Fryer
To remove the pan assembly, first remove the unit from
the installation, then (See Figure 3-50):
1.
Remove the front access panel.
2.
Remove the thermodisc fryer, and the main RTD
from the pan assembly.
2.
Remove the rear access panel and disconnect the
steamer fill sensor RTD from the pan stud.
3.
Disconnect the wire harness from the user
interface.
4.
Turn the unit over and remove the manual shut off
valve.
5.
Extract the two inner screws from the front
enclosure.
6.
Extract the two screws from the rear panel.
7.
Lift the pan assembly straight up and remove the
pan assembly.
Element Steamer, Fryer
To remove the element steamer, fryer, first remove the
pan assembly, then (See Figure 3-51):
1.
Disconnect the element wires.
2.
Use a T-15 Torx bit to extract the screws from the
element supports.
3.
Remove the element support with the element
steamer, fryer attached.
4.
Extract the screws on the rear of the element sup-
port and remove the element steamer, fryer.
Figure 3-50. FM15 Pan Assy Steamer, Fryer
Figure 3-51. FM15 Element Steamer Fryer