Page 27
Electronics and Gas Theory
Integrated Modules
Integrated Modules
2-17
#826498 - Revision B - December, 2016
b.
Annunciator Frequency - All Models
Two
“.”
displayed on the rear control zone.
•
TM15TF/S
- two
“.”
displayed on the front control zone.
•
Fr
displayed on the 2-digit display.
•
The
“.”
displayed on the front left control zone shows the current frequency level.
•
Power level 1 for low, power level 5 for medium, and power level 10 for high.
•
As the frequency is adjusted, the annunciator sounds a tone at the newly selected setting.
1.
Touch the front control zone
MLT/SIM
pad or
HI
pad to adjust the frequency up or down.
•
TM15TF/S
- touch the front control zone
LO
pad or
HI
pad to adjust the frequency up or down.
•
A touch of the
“+”
pad advances the user options mode to Auto-Lock.
2.
c.
Auto-Lock - All Models except TM15TF/S
Three
“.”
displayed on the rear control zone.
•
Auto-lock function is enabled by default.
•
If disabled, the unit does not automatically enter lock mode after 10 minutes of continuous idle mode.
•
Three
“.”
displayed on of the rear control zone.
•
Lo
is displayed in the 2-digit display.
•
Touch the front control zone
MLT/SIM/LO
pad to disable the auto-lock function. The front left control zone
1.
power level changes to level one..
Touch the front control zone
HI
pad to enables the auto-lock feature. The front left control zone power level
2.
changes to level ten.
CE152TF/S
,
CI152TF/S
, and
GM15TF/S
- a touch of the
“+”
pad advances the user options mode to
3.
Sabbath Mode.
SM15TF/S
and
FM15TF/S
- a touch of the
“+”
pad advance the user options mode to Temperature Offset.
4.
d.
Temperature Offset - SM15TF/S and FM15TF/S
Four
“.”
displayed on the rear control zone.
•
OF
is displayed in the 2 digit display when Temperature Offset is engaged.
•
Temperature offset is displayed in the 3 digit display and set to zero by default.
•
Touch of the temperature
“-”
pad or
“+”
pad adjusts the temperature offset up or down.
•
The left digit of the 3 digit display shows a
“-”
for a negative offset and is blank for a positive offset.
•
Maximum offset is ± 10° F.
•
”-”
pad returns to Auto-lock user option and
“+”
pad advances to Temperature Units user option.
•
e.
Temperature Units - SM15TF/S and FM15TF/S
Five
“.”
displayed on the rear control zone.
•
Un
is displayed in the 2 digit display when Temperature Units is engaged.
•
F
or
C
is displayed in the 3 digit display depending on which units are currently selected.
•
Touch of the temperature
“-”
pad or
“+”
pad toggles between
F
or
C
.
•
“-”
pad returns to Temperature Offset.
•
SM15TF/S
-
“+”
advances to Sabbath Mode.
•
FM15TF/S
-
“+”
advances to Annunciator user option.
•
f
.
Sabbath Mode - CE152TF/S
Four
“.”
displayed on the rear control zone.
•
A touch of the front control zone
HI
pad will engage Sabbath Mode.
1.
A touch of the front control Zone
MLT/SIM
will disengage Sabbath Mode.
2.
SA
is displayed in the 2 digit display when Sabbath Mode is engaged.
•
When Sabbath Mode is engaged all displays will be turned off at all times with the exception of the
SA
•
in the 2 digit display and the hot surface indicator.
When Sabbath Mode is engaged there will be no annunciator tones. The only exception would be a pri-
•
ority 1 error, in which case the error would sound and the unit would disengage Sabbath Mode and
enter an Error Mode.
During Sabbath Mode, the hot surface indicator will be visible at all times.
•
During Sabbath Mode there will be no operational time limit.
•
All element assemblies and power levels will otherwise function normally in Sabbath mode.
•