Page 73
Integrated Modules
Integrated Modules
Troubleshooting
4-12
#826498 - Revision B - December, 2016
E20
E21
E22
E23
E24
E25
E26
HOT_LED_STATUS
DISPLAY_MICRO_INTERNAL_
ERROR
EE_AUDIT_ERROR_
CONFIG_DATA
EE_AUDIT_ERROR_
USER_OPTIONS
KEY_MICRO_INTERNAL_
ERROR
OUTPUT_DRIVER_ERROR
ZERO_CROSS_MISSING
HOT LED does not reflect
commanded state
HOT not lit - RTD Steam
•
Fill is > 140°F
HOT lit - RTD Steam Fill is
•
< 122°F
GM15: HOT not lit after
•
cooking > 5 minutes
GM15: HOT lit after Off for
•
> 30 minutes
LED display internal error (user
interface error reported 3 times
in 40 seconds)
Config data in EEPROM cor-
rupted; defaults used after
micro reset
User option data in EEPROM
corrupted; defaults used after
micro reset
Cap-touch keypad micro
internal error (Cap-touch error
reported 3 times in 40 sec-
onds)
Output Driver watchdog has
detected an error
Zero cross input signal is not
present
1. Cycle unit power.
2. Check resistance RTD Steam
Fill sensor.
3. Replace user interface.
1. Cycle unit power.
2. Replace user interface.
1. Cycle unit power.
2. Replace module power board.
1. Cycle unit power.
2. Replace module power board.
1. Cycle unit power.
2. Replace user interface.
1. Cycle unit power.
2. Replace module power board.
1. Cycle unit power.
2. Replace module power board.
General Errors - SM15TF/S, FM15TF/S, and GM15TF/S
Code
Description
Test