Page 65
Integrated Modules
Integrated Modules
Troubleshooting
4-4
#826498 - Revision B - December, 2016
b.
Power Level Readout - SM15TF/S, FM15TF/S and GM15TF/S
Touch
“+”
pad during the LED test.
1
Two
“.”
are displayed on rear control zone.
2
Touching the front or rear control zone indicates the power level in the temperature display.
3
LO
displays the power level of 0.
4
HI
displays the power level of 255.
5
“-”
pad engages LED Test and
“+”
pad engages Control Temperature Readout.
6
c.
Control Temperature Readout - CE152TF/S, CI152TF/S, and TM15TF/S
Touch
“+”
pad during Unit Reconfiguration.
1
CE152TF/S
and
CI152TF/S
- three
“.”
are displayed on rear control zone.
•
TM15TF/S
- three
“.”
are displayed on front control zone.
•
2-digit display shows the ambient control temperature in °C.
•
Over 99° C (210° F), the decimal point of the 2 digit display turns on to indicate the temperature is
•
100° C or higher.
“-”
pad returns to Unit Reconfiguration and
“+”
pad advances to Heat Sink Temperature.
2
c.
Control Temperature Readout - SM15TF/S, FM15TF/S, and GM15TF/S
Touch
“+”
pad during Power Level Readout.
1
Three
“.”
are displayed on rear control zone.
•
The temperature display shows the ambient control temperature in °C.
•
“-”
pad returns to Power Level Readout and
“+”
pad advances to Heat Sink Temperature.
2
d.
Heat Sink Temperature Test - CE152TF/S
Touch
“+”
pad during the Control Temperature Readout.
1
Four
“.”
are displayed on the left rear control zone.
•
2-digit display shows 00. There is no state on the CE152TF/S.
•
“-” pad returns to Control Temperature Readout and “+” pad advances to Coil Temperature test.
2
d.
Heat Sink Temperature Test - CI152TF/S
Touch
“+”
pad during Control Temperature Readout.
1
Four
“.”
are displayed on the left rear control zone.
•
2-digit display shows the current heat sink state.
•
“0”
- temperature is ≤ 176° F - unit works correctly.
•
“1”
- temperature is > 176° F - boost is disabled for affected zone.
•
“2”
- temperature is > 192° F and ≤ 201° F - zone limited to 60% power.
•
temperature is > 201° F and ≤ 210° F - zone limited to 40% power.
•
“3”
- temperature is > 210° F - zone turns off.
•
“-”
pad returns to Control Temperature Readout and
“+”
pad advances to Coil Temperature test.
2
d.
Heat Sink Temperature Test - TM15TF/S
Touch
“+”
pad during Control Temperature Readout.
1
Four
“.”
are displayed on the front control zone.
•
2-digit display shows the current heat sink state.
•
“0”
- temperature is ≤ 176° F - unit works correctly.
•
“1”
- temperature is > 176° F - unit works correctly (no boost).
•
“2”
- temperature is > 192° F and ≤ 201° F - zone limited to 60% power.
•
temperature is > 201° F and ≤ 210° F - zones limited to 40% power.
•
“3”
- temperature is > 210° F - zone turns off.
•
“-”
pad returns to Control Temperature Readout and
“+”
pad advances to Coil Temperature test.
2