Page 16
Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-6
#826498 - Revision B - December, 2016
Lock Mode - All Models
No pad can function except for the
LOCK
pad or the pads associated with entering Diagnostic Mode.
Entering Lock Mode
Enter lock mode by holding
LOCK
pad for 3 seconds when in Idle Mode.
1.
Engages after ten continuous minutes of Idle Mode.
•
After power up sequence.
•
Annunciator sounds Acceptance beep when Lock Mode is entered.
•
LOCK
LED is visible.
•
Annunciator sounds Failure beep if any control zone is active when trying to enter Lock Mode.
•
Exiting Lock Mode
Touch and hold the
LOCK
pad for 3 seconds.
1.
CE152TF/S
and
CI152TF/S
- if
LOCK
pad is held for more than 10 seconds unit relocks.
•
SM15TF/S, FM15TF/S, GM15TF/S, and TM15TF/S - if
LOCK
pad is held for more than 7 seconds unit
•
relocks.
Annunciator sounds Acceptance beep to indicate Lock Mode has been exited.
•
LOCK
LED turns off and control zones enter Idle Mode.
•
Valid key presses in Lock Mode
LOCK
pad for exiting Lock Mode.
•
CE152TF/S
,
CI152TF/S
, and
TM15TF/S
- touch and hold
“+”
and
“-”
pads for 5 seconds to enter
•
Diagnostic Mode.
SM15TF/S
,
FM15TF/S
, and
GM15TF/S
- touch and hold
“ALL OFF”
pad for 5 seconds to enter Diagnostic
•
Mode.
Display states in Lock Mode
LOCK
display is on.
•
All other displays are off.
•
Idle Mode - All Models
Unit is unlocked and control zones are inactive.
Valid key presses in Idle Mode
LOCK
– Touch and hold
LOCK
pad to enter Lock Mode.
•
ON/OFF
– Touch any control zone
ON/OFF
pad places that control zone in Wake-Up Mode.
•
TIMER
– Touch
TIMER
pad activates the Timer.
•
DRAIN
- SM15TF/S - liquid temperature below 140° F, a touch and hold of the
DRAIN
pad for three seconds
•
results in an audible chime and the drain valve will open for two minutes.
Display states in Idle Mode
All displays are off.