Page 25
Electronics and Gas Theory
Integrated Modules
Integrated Modules
2-15
#826498 - Revision B - December, 2016
f.
Error Code Indicator - CE152TF/S, CI152TF/S and TM15TF/S
Touch
“+”
pad during the Coil Temperature test.
1.
CE152TF/S
and
CI152TF/S
- six
“.”
are displayed on rear control zone.
•
TM15TF/S
- six
“.”
are displayed on front control zone.
•
CE152TF/S
and
CI152TF/S
- front control zone shows 0-8 dimmed
“.”
based on how many error codes
•
are logged.
TM15TF/S
- rear control zone shows 0-8 dimmed
“.”
based on how many error codes are logged.
•
Fully lit LED indicates which error is being displayed in the 2-digit display.
•
If only a single error has been logged, only a single fully lit LED is displayed.
•
If no errors logged
SIM/MLT/LO
,
HI
, and
“.”
are not displayed and “- -” is displayed in the 2-digit display.
•
2-digit display shows the corresponding error code stored in memory.
•
Rear
SIM/MLT/LO
and
HI
are dimmed. A touch of the front control zone
SIM/MLT/LO
or
HI
pads cycles
2.
through the stored error codes.
Touch and hold
TIMER
pad for 5 seconds to clear error code history.
3.
Clearing the error code history is only possible if at least one error was logged.
•
Clearing the error code history is confirmed by a double beep.
•
If an error is currently present when the log is cleared, it immediately regenerates an error code.
•
“-”
pad returns to Coil Temperature test and
“+”
pad advances to Showroom Mode menu.
4.
f.
Error Code Indicator - SM15TF/S, FM15TF/S and GM15TF/S
Touch
“+”
pad during the RTD Temperature test.
1.
Five
“.”
are displayed on rear control zone.
•
Front control zone shows 0-8 dimmed
“.”
based on how many error codes are logged
•
Fully lit LED indicates which error is being displayed in the 2-digit display.
•
If only a single error has been logged, only a single fully lit LED is displayed.
•
If no errors logged
LO
, and
HI
, and
“.”
are not displayed and “- -” is displayed in the 2-digit display.
•
2-digit display shows the corresponding error code stored in memory.
•
A touch of the front control zone
LO
or
HI
pads cycles through the stored error codes.
2.
Touch and hold
TIMER
pad for 5 seconds to clear error code history.
3.
Clearing the error code history is only possible if at least one error was logged.
•
Clearing the error code history is confirmed by a double beep.
•
If an error is currently present when the log is cleared, it immediately regenerates an error code.
•
“-”
pad returns to RTD Temperature test and
“+”
pad advances to Showroom Mode menu
4.
g.
Showroom Mode - CE152TF/S, CI152TF/S, and TM15TF/S
Touch
“+”
pad during the Error Code Indicator.
1.
CE152TF/S
and
CI152TF/S
- Seven
“.”
displayed on rear control zone.
•
TM15TF/S
- Seven
“.”
displayed on front control zone.
•
To engage showroom mode.
2.
CE152TF/S
and
CI152TF/S -
touch the front control zone
HI
pad to engage showroom mode.
•
TM15TF/S
- touch the rear control zone
HI
pad to engage showroom mode.
•
SH
is displayed in the 2-digit display when in showroom mode.
•
To disengage showroom mode.
3.
CE152TF/S
and
CI152TF/S
- touch the front control zone
SIM/MLT
pad.
•
TM15TF/S
- touch the rear control zone
LO
pad.
•
”-”
pad returns to Error Code indicator and
“+”
pad advances to Software Version indicator.
4.
g.
Showroom Mode - SM15TF/S, FM15TF/S, GM15TF/S
Touch
“+”
pad during the Error Code Indicator.
1.
Six
“.”
displayed on rear control zone.
•
To engage showroom mode.
2.
Touch the front control zone
HI
pad to engage showroom mode.
•
SH
is displayed in the 2-digit display when in showroom mode.
•
To disengage showroom mode.
3.
Touch the front control zone
LO
pad.
•
”-”
pad returns to Error Code indicator and
“+”
pad advances to Software Version indicator.
4.