PAGE 54 OF 126
NIGHT SCAN VERTICAL, VERTICAL COMPLETE, AND VERTICAL HDT
OPERATING INSTRUCTIONS
TP-4836201-H
MAY 2021
5.7 Attaching the RCP to the Mast
To attach the RCP to the mast:
1. Ensure the power is off.
Note: The RCP is not shipped in the Auto Stow
®
position for the light tilt angle. The unit may
rotate the light fixtures as soon as power is applied for the first time.
2. Attach the 4-circuit male plug from the RCP to the 4-circuit female plug from the mast. This is
the data cable.
3. Attach the 10-circuit male plug from the RCP to the 10-circuit female plug from the mast. This
is the power cable.
4. Tuck the wires in and place the RCP on the mast while being careful not to pinch the wires.
5. Orient the RCP in the desired direction noting the RCP shipped in the Auto Stow
®
position for
panning. Connect the RCP and mast with the four provided screws and washers (see Figure
5-20). Torque the screws to 7-8 Nm (62-70 in.-lb.). Once all four screws are tight, re-torque
each screw a second time to ensure that tightening one screw did not loosen another on the
diameter. Each screw must be installed with low strength Loctite (blue).
Figure 5-20 RCP Installation
RCP Installation
Screws
Summary of Contents for Night Scan Vertical 4.3-15