PAGE 117 OF 126
NIGHT SCAN VERTICAL, VERTICAL COMPLETE, AND VERTICAL HDT
OPERATING INSTRUCTIONS
TP-4836201-H
MAY 2021
GRN
VIO
GRY
VIO
(init)
WHT
BLK
RED
BLK
(kill)
(com)
PANEL MOUNT
REMOTE CONTROL
KILL
INITIATE
BRN
BLU
RED 10 GA
BLK 10 GA
2
8
TO BASE BOARD - SEE SYSTEM WIRING DIAGRAM
INTERCONNECT CABLES
A. DC & CONTROL CABLE,
WITH
CONNECTOR
OR
B. DC & CONTROL CABLE,
WITHOUT
CONNECTOR
OR
C. CONTROL CABLE
ONLY
(DOES
INCLUDE 10 GA
RED & BLACK, 18 GA RED & BLACK
TWISTED PAIR)
GRN/YEL
7
BLK
WHT
BLK
RED
GRY
VIO
GRN
(init)
(com)
(kill)
J4 ON BASE BOARD
JUMPER FROM 5-7 REQUIRED
FOR STANDARD (NON-NFPA) OPERATION
4
5
2
CONNECT SHIELD
GROUND TO J4-2
(N/A ON CABLE "A")
VIO
CONNECT SHIELD
GROUND TO PIN 2
IF USING CABLE "A".
PMRC
915377
4858701
4858703
4858702
4858704
4
3
3
KITS
4735002
4735021 4735022
4756921 4756922
4
CUSTOMER SUPPLIED
NOT USED ON 915377
FACEPLATE
C
C
DJB
JDN
NOTES
1. TORQUE: 4.4in-lbs, 0.5Nm
2. "MAST ACTIVE" CONTACTS, J-K OR J4 9,10:
USE SW2-1 ON BASE BOARD TO SELECT OPEN (OFF) OR CLOSED (ON) WHEN NESTED.
SW2-1 OPEN = CONTACTS CLOSED WHEN NESTED
SW2-1 CLOSED = CONTACTS OPEN WHEN NESTED.
2 AMPS MAX CURRENT, 20 GA. MINIMUM CONDUCTOR. CUSTOMER SUPPLIED WIRING.
3. SW2-2 ON BASE BOARD MUST BE OPEN (OFF) FOR NFPA MODE.
4. SW2-2 ON BASE BOARD MUST BE CLOSED (ON) STANDARD MODE.
5. REMOVE JUMPER(S) IF REPLACED BY PARKING BRAKE INTERLOCK. G-H CLOSED WHEN BRAKE "ON".
AVAILABLE IN STANDARD MODE ONLY.
6. 4521802 CABLE: ALL WIRES 20 GA. EXCEPT RED AND BLACK (J4-1 AND 2).
7. OPTIONAL DISABLE INPUT, CUSTOMER SUPPLIED CONTACTS. MUST HAVE CONTINUITY TO FUNCTION. WILL
NOT ALLOW OPERATION IF OPEN, ACTS AS EMERGENCY STOP
8. BATTERY CONNECTION TO SYSTEM: IN-LINE SPLICE RECOMMENDED. DO NOT USE TERMINALS E & F.
9. 18 GA. MIN. IF USING 4521802 SIGNAL CABLE TO BASE BOARD WITH SEPARATE 10GA TO BASE BOARD.
nightscan
UNIVERSAL CONTROL
SINGLE HARD-WIRED
PANEL MOUNT REMOTE CONTROL
™
NSU J-Box Wiring3.dwg
BY/APPVL
DJB/JMK
DJB/JMK
DJB/JLK
DJB/AW
Summary of Contents for Night Scan Vertical 4.3-15