PAGE 70 OF 126
NIGHT SCAN VERTICAL, VERTICAL COMPLETE, AND VERTICAL HDT
OPERATING INSTRUCTIONS
TP-4836201-H
MAY 2021
6.3 Quick Operation Summary
The following is a quick summary of the operation of the system. Detailed steps follow the quick
summary.
If an emergency stop (E-Stop) is required at any time, press the “E-Stop” button. This
disconnects the unit from power and causes all air to be exhausted from the mast. The mast fully
lowers (if it was raised) regardless of the orientation of the RCP.
1. Ensure the vehicle is stationary and the parking brake is engaged.
2. Ensure there are no obstructions in the mast operating space.
3. If the “E-Stop” was activated, it must be reset by turning to enable the system to power-up.
Do not reset the “E-Stop” until the cause of the event is corrected. Turn the red “E-Stop”
button if needed. Then press "NFPA Start" to power-up the mast.
4. Raise the mast by pressing and holding the “Mast Up” button. Then press the “Lights” to turn
the lights on.
5. If desired, raise the mast further by pressing “Mast Up”.
6. Position the lights vertically by pressing “Tilt Down” and “Tilt Up”.
7. Position the lights horizontally by pressing "Pan Right" and "Pan Left".
8. Use the "AUX" button to turn on the strobe/beacon light (if equipped).
9. If desired, lower the mast by pressing "Mast Down".
10. Stow the mast by performing one of the following steps:
• Quickly press "Mast Down" twice (Auto Stow® feature). It is recommended to use the Auto
Stow® feature to stow the mast. To abort Auto Stow®, press any controller button.
• Press and hold "Mast Down" until all LEDs on the controller turn off. Ensure that "Mast Down"
is released only after the controller LEDs turn off, which means the mast is stowed.
Summary of Contents for Night Scan Vertical 4.3-15