PAGE 27 OF 126
NIGHT SCAN VERTICAL, VERTICAL COMPLETE, AND VERTICAL HDT
OPERATING INSTRUCTIONS
TP-4836201-H
MAY 2021
4 Technical Data
Night Scan Vertical
NS
Vertical
Complete
NS
Vertical
HDT
4.3-15
5.4-17
6-20
7-25
8-30
Extended Height (ft / m)
13.4 / 4.08 17 / 5.2 20.4 / 6.2 25.4 / 7.7 30.4 / 9.2 7.5 / 2.3
15 / 4.5
Nested Height (ft / m)
4.5 / 1.3 5.5 / 1.68 6.1 / 1.9 7.1 / 2.2 8.1 / 2.5 5.3 / 1.6 5.75 / 1.8
Mast Control System Input Voltage
12VDC - 24VDC
Mast Control System Current
14A Max at 12VDC 10A Max at 24VDC
Lighting Input Voltage (for DC lights)
12VDC - 24VDC
Lighting Current (for DC lights)
50A Max at 12VDC 25A Max at 24 VDC
Lighting Input Voltage (for AC lights)
110VAC - 220VAC (50 or 60 Hz)
Lighting Current (for AC lights)
38A Max at 110VAC 28A Max at 220VAC
System Operating Temperature
-22 to 149 °F / -30 to 65 °C
System Storage Temperature
-40 to 149 °F / -40 to 65 °C
Deployment Angle
±5° Maximum
Deployment Wind Speed (mph / km/h)
40 max / 64 max
Altitude Above Sea Level (ft / m)
15,000 / 4572 Maximum
*Survival Wind Speed (mph / km/h)
119-140+ /
191-225+
100-121 /
160-195
87-104 /
140-167
73-86 /
117-138
63-73 /
101-117
119-140+ /
191-225+
100-121 /
160-195
Auto Stow
®
Yes
Number of Lights Available
4 or 6
2 or 4
6
Light Type Available
LED or Halogen
LED Spot/
Flood
Maximum Lumens
220,000 220,000 220,000 220,000 220,000 140,000
220,000
Full Pan and Tilt Light Positioning
Yes
Opposable Light Fixtures
Yes
No
Yes
Profiler - Space Saving Fixture Option
Yes
No
No
Strobe Light Option Available
Yes
D-TEC Powerline Detection System
Option
Yes
No
Yes
Camera Option Available
Yes
**Airborn Noise Emissions
equivalent A-weighted sound pressure level at the operating position is less
than 70 dB(A)
*Varies depending on light package - NFPA 125% Safety Factor
**Measured according to EN ISO 3744:2010