PAGE 107 OF 126
NIGHT SCAN VERTICAL, VERTICAL COMPLETE, AND VERTICAL HDT
OPERATING INSTRUCTIONS
TP-4836201-H
MAY 2021
2,11
Right Tilt Up wrap
around
The software indicates
the same photosensor
was made before the
opposite limit
photosensor was made
to stop rotation. This
indicates wrap around
1. The flag that
interrupts the light may
need to be adjusted to
go deeper into the
photocell.
2. The limit photo sensor
is defective
2,12
Right Tilt Down wrap
around
2,13
Pan Right wrap around
The software indicates
the same photo sensor
was made before the
opposite limit photo
sensor was made to
stop rotation. This
indicates wrap around
The limit photo sensor is
defective
2,14
Pan Left wrap around
2,15
Left Tilt Limit Overlap
The software indicates
both tilt photo sensors
appear to be blocked
simultaneously
Foreign material in one
of the photo sensors or
faulty photo sensor
2,16
Right Tilt Limit Overlap
Table 9-3 Error and Warning Codes for HHRC
Message
Meaning
Root Issue
Potential Cause
WRN 3,02
Dual HHRC
simultaneous inputs
Two HHRCs are
sending commands
simultaneously.
If commands are not
conflicting, they will be
allowed (Base Board
decides).
If commands are
conflicting, no action/
movement will be
allowed by the Base
Board.
Warning appears
regardless of conflicting
or not conflicting to alert
operators that someone
else is trying to operate
the unit simultaneously
Multiple users
controlling the mast
Table 9-2 Error and Warning Codes for RCP (Continued)
Message
Meaning
Root Issue
Potential Cause
Summary of Contents for Night Scan Vertical 4.3-15