8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 111
Section 8.11
: Level “Configuration” (A parameters)
Safety chain function “remote start”
Range
Def.
A38 Safety chain for function ‚remote start‘
Monitoring of manhole and rinsing tank.
See parameter [A21..A33] selection 28: 29: 30:
Connection see section 9.12
0..1
0
0: Safety chain in control line of remote push-buttons
1: Safety chain via digital input
Output signal configuration robot
Range
Def.
A40 Robot operation / control pneum. butterfly valve
0..3
0
0: without robot and without pneumatic butterfly valve
1: only with robot
2: only butterfly valve control (pneumatic)
3: robots and pneum. butterfly valve control active
A41 Robot stop signal configuration (see section 4.6)
0..3
0
0: closing contact, robot stopped when closed
1: closing contact, robot stopped when open
2: opening contact, robot stopped when closed
3: opening contact, robot stopped when open
A42 Robot release delay
Delays the robot release by the set time.
During this time, the "Robot STOP" LED flashes.
0..60 sec.
0
Alarm relay configuration
Range
Def.
A45 Relay configuration “alarm in general“
Parameter [A1..A20] => 14
0: closing contact, alarm if closed
1: closing contact, alarm if open (non-volatile)
2: opening contact, alarm if closed (non-volatile)
3: opening contact, alarm if opened
0..3
0
A46 Configuration “alarm tank monitor“
Parameter [A1..A20] => 1
0: closing contact, alarm if closed
1: closing contact, alarm if open (non-volatile)
2: opening contact, alarm if closed (non-volatile)
3: opening contact, alarm if opened
0..3
0
A47 Configuration „red warning light“
Parameter [A1..A20] => 19
0: is reset during the cleaning (same as red LED)
1: is reset with pressure
0..1
0
The settings in A45 to
A47 are only active if the
corresponding output
function is assigned to a
relay in the parameters
A1 to A20:
A45 = 14
A46 = 1
A47 = 19