9. Other information
– General
Page 124
105204
– WTS-300-E - V4.1 - 20.01.2022
9.8 Agitator monitoring module (optionally)
For different applications 4 different agitator monitoring modules are available:
The ESVAW-001-A monitoring module is designed for monitoring up to 4 agitator
motors. In the standard version only the motors A and B are supported motors C and
D are optional usable.
The agitator monitoring module ESVAW-002-A is used to monitor max. 2 agitator
motors in milk cooling tanks. The agitator motors can be switched on or off directly
via the module via the integrated relays. Thus, e.g. on a cooling tank control no relay
for switching the agitator motors are occupied.
The agitator monitoring module ESVAW-003-A is designed to monitor a three-phase
AC motor with 400V AC.
The ESVAW-004-A monitoring module is designed for monitoring up to 4 agitator
motors. In the standard version only the motors A and B are supported motors C and
D are optional usable.
The monitoring module is determining the power input independently for each con-
nected motor and hereof it will be deduced whether the respective motor rotates and
whether it runs with or without load so that a defective stirring wing can be detected
for example.
The module has to be configurated in parameter [A71].
For the correct installation please pay attention to the supplied documentation
of the respective module.