8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 107
Fault configuration...
Setting
Def.
F1
F2
F3
... milk temperature too high for too long high1
... milk temperature too high for too long high2
... milk temperature too high for too long high3
12 .. 13
12 .. 13
12 .. 13
13
13
13
F6 ... power failure alarm
12 .. 13
13
F11
F12
... minimum cleaning temperature not reached
... minimum cleaning time at temp. not reached
7 .. 13
7 .. 13
11
11
F15
F16
... agitator fault in cooling mode
... timeout "No agitator action"
7 .. 13
7 .. 13
11
11
F20 ... cooling time exceeded for first milking
7 .. 13
11
F22 ... Cooling not switched on
7 .. 13
11
F23
F25
F26
... milk temperature too high for too long
... over-temperature directly
…
max. running time of compressor cycle exceeded
7 .. 13
7 .. 13
7 .. 13
11
11
11
F27
F29
... milk temperature too long too low
... under-temperature directly
7 .. 13
7 .. 13
11
11
F30 ... power failure (direct)
7 .. 13
11
F31
F32
F33
F34
F35
F36
F37
F38
F39
... max. time without cleaning (after end cool. mode)
... max. time without cooling (after cleaning mode)
... min. cleaning interval
... time / date not set
...
Detergent dispenser empty ‚alkaline'
...
Detergent dispenser empty ‚acid'
… Disinfectants
... temp. difference exceeded monitoring sensor
... battery voltage too low
7 .. 13
7 .. 13
7 .. 13
7 .. 13
7 .. 13
7 .. 13
7 .. 13
7 .. 13
7 .. 13
11
11
11
11
11
11
11
11
11
F40
F41
F42
... safety switch butterfly valve
... pressure switch cleaning pipe
... thermos contact cleaning pump
1 .. 13
1 .. 13
1 .. 13
6
6
6
F43
F44
F45
F46
F48
F49
... manual interruption of cleaning
... timeout water intake by level
... water in the tank after draining
... Fault water intake
... timeout heating time cleaning
... over-temperature monitor heater
1 .. 13
1 .. 13
1 .. 13
1 .. 13
1 .. 13
1 .. 13
6
6
6
6
6
6
F51
F52
F53
F54
F55
F56
F57
F58
... Tank-overflow protection
... water in tank cooling mode
... Thermal protec. - / fault monitoring compressor
... agitator-condition monitoring direct
... Timeout quantity-dependent cooling start
... broken sensor
... sensor short circuit
... sensor range exceeded
1 .. 13
1 .. 13
1 .. 13
1 .. 13
1 .. 13
1 .. 13
1 .. 13
1 .. 13
6
6
6
6
6
6
6
6
F60
F61
F62
... Error external sensors
... Error ESGSM or ESIPM module
... I/O expansion module
1 .. 13
1 .. 13
1 .. 13
6
4
6
F80
F81
F82
F83
F85
... Message low pressure
... Message high pressure
… external fault
... Malfunction analog input 4..20 mA
... Phase error
1 .. 13
1 .. 13
1 .. 13
1 .. 13
6
6
6
6
F99 ... Test alarms (see section 9.5)
1 .. 13
11
je nach Einstellung
informativer oder kritischer
Tankwächteralarm
oder auch Systemalarm
(grüne oder rote LED
oder nur Displayanzeige)
Depending on the setting,
it is an informative or a
critical tank monitor alarm
(green or red LED)
Critical
tank monitor alarm
(always red LED)