8. Setting of parameters
Page 114
105204
– WTS-300-E - V4.1 - 20.01.2022
Section 8.11
: Level “Configuration” (A parameters)
Range
Def.
A72 activation detergent monitoring
by conductometry
0: deactivated
1: activated
0 .. 1
0
A73 activation alarm module monitoring F61
ESGSM modem / ESIPM modem
0: deactivated
1: activated, do not forward alarm messages
2: activated, forward tank guard alarms
3: activated, forward general alarms
4: activated, forward all alarms
0 .. 4
0
A74 Activation of the I/O extension module F62
0: deactivated
1: activated, no current monitoring
2: activated, fault monitoring 1st channel
(cable break <3.5 mA) active
0 .. 2
0
A75 Operating mode 12V input
See section 9.7
0: Input not used
1: Battery operation with power failure monitoring
2: Operation via external power pack,
Power failure monitoring is deactivated
0 .. 2
0
Automatic change of daylight saving time
Range
Def.
A78 Automatic change of daylight saving time
0 .. 3
2
0: deactivated
1: Western European time zone (change at 1:00)
2: Central European time zone (change at 2:00)
3: Eastern European time zone (change at 3:00)
Test parameter for the agitator rating
Range
Def.
A80 Rating limit agitator
-1: more sensitive
0: normal
1: less sensitive
-1 .. 1
0
Activate phase monitoring relay ESVAW-003
Range
Def.
A85 Activate phase monitoring relay
ESVAW-003
(F85)
0 .. 4
1
0: deactivated
1: activated, the relay on the module drops off in case of an error
2: Additional compressor protection. In case of an error
the compressor is switched off
3: Additional cleaning pump protection. In case of an error
the cleaning is interrupted
4: Additional compressor protection and cleaning pump protection.