8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 109
Assignment of output functions to relays
0:
deactivated
1:
alarm tank monitor *
2:
robot stop
3:
detergent „acid“
4:
heater
5:
cleaning pump
6:
drain valve 1
7:
pneumatic butterfly valve
8:
detergent „alkaline“
9:
warm water
10:
cold water
11:
compressor 1 / 1. cooling level
12:
agitator
13:
cleaning active
14:
alarm in general *
15:
drain valve 2
16:
hot water valve / Beaker cleaning
17:
disinfection
18:
compressor 2 / 2. cooling level
19:
external alarm light
20: compressor 3 / 3. cooling level
21:
Boost pump
22:
Output multifunction relay
23:
Set level 2 on the relay (see section 11.7)
24: Off mode active
25: Cooling active
26: Milk transfer valve
Range
Def.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A15
A16
A17
A18
A19
A20
assignment relay K1
assignment relay K2
assignment relay K3
assignment relay K4
assignment relay K5
assignment relay K6
assignment relay K7
assignment relay K8
assignment relay K9
assignment relay K10
assignment relay K11
assignment relay K1
– I/O module (optionally)
assignment relay K2
– I/O module (optionally)
assignment relay K3
– I/O module (optionally)
assignment relay K4
– I/O module (optionally)
assignment relay K5
– I/O module (optionally)
assignment relay K6
– I/O module (optionally)
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
0 .. 26
1
2
3
4
5
6
7
8
9
10
11
12
0
0
0
0
0
0
* The alarm relay con-
figuration for output
functions 1 and 14 is
done in parameters
A45 and A46.
Al
a
rm
h
o
rn
(Ta
n
k
m
o
n
ito
ri
n
g
a
la
rm
)
Rob
o
t
STOP
Ac
id
d
e
te
rg
e
n
t
L1
–
Sup
pl
y
Hea
te
r
Cle
a
n
ig
p
u
m
p
Drai
n
v
a
lv
e
Bu
tt
e
rfl
y
v
a
lv
e
Al
k
a
lin
e
d
e
te
rg
e
n
t
Wa
rm
wa
te
r v
a
lv
e
L1
–
Sup
pl
y
Col
d
wa
ter
v
a
lv
e
Com
p
re
s
s
o
r
Ag
ita
to
r