8. Setting of parameters
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 103
Setting milk times to monitor „cooling activated”
Fault
Range
Def.
This function triggers an alarm if cooling has not been activated at the
entered milk times. This is to prevent to forget the activation of the cool-
ing in case of the first milking after the cleaning.
h41 milk time 1
F22 00:00..23:59 --:--
h42 milk time 2
F22 00:00..23:59 --:--
h43 milk time 3
F22 00:00..23:59 --:--
Settings tank monitor LOG files
h82 Fault indicator for external faults
Input function digital input [A21..A33] => 37 (fault indicator)
F82
0 .. 2
0
0: deactivated
1:
„High-active“ *
Fault when contact opened
2:
„Low-active“ *
Fault when contact closed
* The signal must be permanently ready for use
h89 Saving of additional information in LOG-memory
0: deactivated
1: Temperature 2
2: Performance of stirring unit first stirring unit
3: Measuring size analogue input (4..20 mA)
0 .. 3
0
h90 Selection period (in days) of the recording data (Konsoft)
1 .. 365
90
h91 Logging intervals cleaning mode in minutes
1 .. 10
1
h92 Logging intervals OFF and cooling mode in minutes
1 .. 30
15
Tank identification
h93 Customer number part 1
(the first 4 digits...)
0 .. 9999
0
h94 Customer number part 2
(the last 4 digits...)
0 .. 9999
0
h96 Tank number part 1
(the first 4 digits...)
0 .. 9999
0
h97 Tank number part 2
(the last 4 digits...)
0 .. 9999
0
Parameter level-locking
h98 Password protection
0 .. FFFF
0
h99 Password protection
0 .. FFFF
0
Explanations to the password protection:
In addition to the level code the level “General tank monitor parameter” can be protected
by another password. A 4-digit password (not 0000) has to be entered in parameter
[h98]. For the activation of the password protection the password in parameter [h99] has
to be repeated exactly.
After the level code is re-entered the password query takes place.