7. Tank monitor and general fault handling
105204
– WTS-300-E - V4.1 - 20.01.2022
Page 63
7.2 Tank monitor: Milk removal YES or NO
Examples of use of tank monitor.
CAUTION:
Do not simply cancel a tank monitor alarm.
It is essential to investigate and remedy the cause, in order to avoid a
harmful effect on the milk.
Even without an alarm message, the plant operator has to convince
himself of the transportability of the milk before picking up!!
No alarm
–
Milk may be drawn off.
The driver goes to the WTS-300 and checks the tank monitor.
If the green LED is on, milk may be drawn off.
Once the milk has been taken, the driver starts the cleaning process.
Informative alarm
–
Milk may be drawn off.
The driver goes to the WTS-300 and checks the tank monitor.
The green LED is flashing - the warn horn sounds - an error code is displayed.
Milk can be drawn off -> The farmer must be informed.
The farmer investigates (and remedies) the cause of the fault and presses the
"RESET" button -> the warn horn mute.
The farmer presses the “RESET“ button again -> the green LED is now on con-
tinuously.
(The informative alarm is accepted and deleted with the pushbutton.)
Once the milk has been taken, the driver starts the cleaning process.
NB:
If the informative alarm is not reset, the green LED flashes and the error code
continues to be displayed -> even after the next cleaning cycle.
Green = on
Red = off
No alarm
Green = flashing
Red = off
Informative alarm
(Press RESET button)
after RESET
Green = on
Red = off
Informativer Alarm
WARNING