8. Setting of parameters
Page 78
105204
– WTS-300-E - V4.1 - 20.01.2022
8.3
Level “Extended cooling parameters” (P parameters)
EMERGENCY COOLING, behaviour on sensor failure
Range
Default
P4
Manual start of compressor for x min.
in case of sensor failure. Function see 10.3
0 .. 60 min.
0
Compressor protection when filling from below
Range
Default
P6
Compressor switch-on delay / pre-agitating
Function see section
0: Function deactivated
1 to 180: Time delay compressor in sec.
0 .. 180 sec.
0
Limit setting for set temperatures and hysteresis
Range
Default
P10
P11
P12
P13
P15
P16
P17
P18
Setting of limitations for target temperatures
and hysteresis in C parameter level.
Lower limit for target temperature T1 - for C1
Upper limit for target temperature T1 - for C1
Lower limit for target temperature T2 - for C2
Upper limit for target temperature T2 - for C2
Lower limit for hysteresis T1 - for C10
Upper limit for hysteresis T1 - for C10
Lower limit for hysteresis T2 - for C11
Upper limit for hysteresis T2 - for C11
0 .. 50,0 °C
0 .. 50,0 °C
0 .. 50,0 °C
0 .. 50,0 °C
0,1 .. 30,0 K
0,1 .. 30,0 K
0,1 .. 30,0 K
0,1 .. 30,0 K
2,0
8,0
2,0
8,0
0,1
2,0
0,1
2,0
Agitator settings
Range
Default
P22 Function intermediate stirring
see section 5.6.3
0: deactivated
1: short / long
2: toggling by button
0 .. 2
1
P23 Automatic start to continuous stirring
when cooling mode ends
see section 10.1.1
0: deactivated
1: activated
0 .. 1
0
Switch to level
“Extended cooling parameters”
See section 8.1
P parameters
Code: D345
Working level
for normal daily operation
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters 1
code: C567
Extended cleaning parameters 2
code: D432
Service parameters
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5