8. Setting of parameters
Page 100
105204
– WTS-300-E - V4.1 - 20.01.2022
8.7 L
evel “Service parameters” (E parameters)
These parameters are only used to query ACTUAL states.
Display tank monitoring time counter and values
Range
Def.
Display off...
E1 ... over- / under time temperature / time 1
0…900 min. - - -
E2 ... over- / under time temperature / time 2
0…900 min. - - -
E3 ... over- / under time temperature / time 3
0…900 min. - - -
Based on the error messages F1 - F3, it can be
read here how long the milk temperature has
already been above the respectively set limit value.
E6 ... the last cleaning temperature reached
0…99,9 °C
- - -
Displays the maximum temperature during the last
cleaning cycle.
E15 ... battery voltage
0,0V..12,0V
- - -
Display the current battery voltage
(Only if optional power pack is installed)
E16 ... of the analog input 4-20 mA
0,0..20,0 mA - - -
Display of the currently measured current
Display of the presently measured current of the
analogue 4..20 mA inputs
Display area
E16 Display of the analogue input 4..20 mA
Display of the presently measured current*.
0,0..20,0 mA
E17 Display of the analogue input 4..20 mA
as [E16] but on IO expansion module I1*.
0,0..20,0 mA
E18 Display of the analogue input 4..20 mA
as [E16] but on IO expansion module I2*.
0,0..20,0 mA
* If the respective input is deactivated, "- -" is displayed
Switch to level
“Service parameters”
See section 8.1
E parameters
Code: EA03
Working level
for normal daily operation
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters 1
code: C567
Extended cleaning parameters 2
code: D432
Service parameters
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5