8. Setting of parameters
Page 98
105204
– WTS-300-E - V4.1 - 20.01.2022
8.6
Level “Extended cleaning parameters 2” (L parameters)
For information on quantity-controlled dosing, see also section 6.5
Rinse cycle quantity setting 0 (Rinse out)
Range
Def.
L1
L2
Amount of water in step n1
Amount of water in step n2
0…500 l
0…500 l
5
50
Rinse cycle quantity setting 1 (Pre-rinse 1)
L12
L13
Amount of water in step n12
Amount of water in step n13
0…500 l
0…500 l
35
0
Rinse cycle quantity setting 2 (Pre-rinse 2)
L22
L23
Amount of water in step n22
Amount of water in step n23
0…500 l
0…500 l
35
0
Rinse cycle quantity setting 3 (Main-rinse 1)
L32
L33
Amount of water in step n32
Amount of water in step n33
0…500 l
0…500 l
50
0
Rinse cycle quantity setting 4 (Intermediate-rinse 1)
L42
L43
Amount of water in step n42
Amount of water in step n43
0…500 l
0…500 l
35
0
Rinse cycle quantity setting 5 (Main-rinse 2)
L52
L53
Amount of water in step n52
Amount of water in step n53
0…500 l
0…500 l
50
0
Rinse cycle quantity setting 6 (Intermediate-rinse 2)
L62
L63
Amount of water in step n62
Amount of water in step n63
0…500 l
0…500 l
35
0
Rinse cycle quantity setting 7 (Disinfection)
L72
L73
Amount of water in step n72
Amount of water in step n73
0…500 l
0…500 l
50
0
Rinse cycle quantity setting 8 (After-rinse)
L82
L83
Amount of water in step n82
Amount of water in step n83
0…500 l
0…500 l
50
0
Rinse cycle quantity setting 9 (Rinse out)
L92
L93
Amount of water in step n92
Amount of water in step n93
0…500 l
0…500 l
5
50
Detergent / disinfectant quantity setting
L101
L102
L103
Amount of detergent alkaline
Amount of detergent acid
Amount of disinfectant
0…10,00 l
0…10,00 l
0…10,00 l
0,30
0,30
0,30
Switch to level
“Extended cleaning parameters”
See section 8.1
L parameters
Code: D432
Working level
for normal daily operation
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters 1
code: C567
Extended cleaning parameters 2
code: D432
Service parameters
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5