8. Setting of parameters
Page 88
105204
– WTS-300-E - V4.1 - 20.01.2022
8.4
Level “General cleaning parameters” (n parameters)
Range
Default
Running times cleaning stage 0 (rinse out) - hidden, if [r40] = 0
n01 Water intake time
0 .. 999 sec.
10
n02 Rinse out time with water intake
0 .. 999 sec.
120
n03 Drain time
0 .. 999 sec.
30
Running times cleaning stage 1 (pre-rinse 1) - hidden, if [r41] = 0
n10 Water intake by feed container *
0 .. 10
0
n11 Water intake by level 1 **
0 .. 1
0
n12 Water intake by time
0 .. 999 sec.
90
n13 Additional water intake time + circulation
0 .. 999 sec.
0
n14 Main circulation time
0 .. 999 sec.
30
n15 Rinse out time
0 .. 999 sec.
0
n16 Drain time
0 .. 999 sec.
60
Running times cleaning stage 2 (pre-rinse 2) - hidden, if [r42] = 0
n20 Water intake by feed container
*
0 .. 10
0
n21 Water intake by level 1 **
0 .. 1
0
n22 Water intake by time
0 .. 999 sec.
90
n23 Additional water intake time + circulation
0 .. 999 sec.
0
n24 Main circulation time
0 .. 999 sec.
30
n25 Rinse out time
0 .. 999 sec.
0
n26 Drain time
0 .. 999 sec.
60
Running times cleaning stage 3 (main rinse 1)
n30 Water intake by feed container
*
0 .. 10
0
n31 Water intake by level 1 **
0 .. 1
0
n32 Water intake by time
0 .. 999 sec.
120
n33 Additional water intake time + circulation
0 .. 999 sec.
0
n34 Main circulation time
0 .. 999 sec.
120
n35 Rinse out time
0 .. 999 sec.
0
n36 Drain time
0 .. 999 sec.
90
Switch to level
“General cleaning parameters”
See section 8.1
n parameters
Code: B454
Working level
for normal daily operation
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters 1
code: B454
Extended cleaning parameters 1
code: C567
Extended cleaning parameters 2
code: D432
Service parameters
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5
**
Applies to all "water
in take by level 1"
situations:
0 = deactivated
1 = activated
*
For all "water intake
by feed container"
the following applies:
0 = deactivated
1..10 = Number of
repetition