8. Setting of parameters
Page 90
105204
– WTS-300-E - V4.1 - 20.01.2022
Section 8.4
: Level “General cleaning parameters” (n parameters)
Range
Def.
Running times cleaning stage 9 (rinse out) - hidden, if [r49] = 0
n91 Water intake time
0 .. 999 sec.
10
n92 Rinse out time with water intake
0 .. 999 sec.
120
n93 Drain time
0 .. 999 sec.
30
Runtime abort for all cleaning stages
n100 Drain time after cleaning has been aborted
0 .. 999 sec.
150
Dosing time settings
n101 Dosing time alkaline detergent
0 .. 999 sec.
30
n102 Dosing time acid detergent
0 .. 999 sec.
30
n103 Dosing time disinfection
(hidden if r47 = 0)
0 .. 999 sec.
30
Temperature settings (see also section 11.3)
n106 Pre-heat. temp. main cleaning stage 1
(alkal./acid)
(hidden if r35 = 0)
0 .. 99,9 °C
45,0
n107 Pre-heat. temp. main cleaning stage 2
(acid)
(hidden if r35 = 0 or 1)
0 .. 99,9 °C
45,0
n108 Pre-heat. temp. main cleaning stage disinfection
(hidden if r35 = 1 or 2)
0 .. 99,9 °C
45,0
n109 Post-heating temp. during circulation in main
cleaning stage 1
[n34] (hidden if r35 = 0)
0 .. 99,9 °C
40,0
n110 Post-heating temp. during circulation in main
cleaning stage 2
[n54] (hidden if r35 = 0 / 1)
0 .. 99,9 °C
40,0
n111 Post-heating temp. during circulation in cleaning
stage disinfection
[n74] (hidden if r35 = 0 / 1 / 2)
0 .. 99,9 °C
40,0