9.12 Safety chain for 'remote start' functions
If the functions CLEANING, COOLINGL and/or STIRRING are triggered
by remote start (push button), the system operator must ensure that
the manhole and the rinsing tank are monitored by a safety chain.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Parameter [A38] => Selection '0'
safety chain in the control line of the remote push buttons
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Parameter [A38] => Selection ‚1‘
Safety chain via digital input
Assign function '36' (release remote start) to one of the digital inputs [A21..A33].
Safety switch
rinsing tank
Safety switch
manhole
Sa
fe
ty
c
ha
in
Safety switch
rinsing tank
Safety switch
manhole
Sa
fe
ty
c
ha
in
Push button remote start COOLING
Push button remote start CLEANING
Push button remote start STIRRING
and / or
and / or
DANGER!
Push button remote start COOLING
Push button remote start CLEANING
Push button remote start STIRRING
and / or
and / or