Printhead Heater Circuit Checks
The Printhead heater circuit can best be checked at the Printhead
PCB, but that involves removing the cover. An alternative is to
conduct continuity tests at the Printhead Data Cable.
1. Turn system off.
2. Remove connector at J1 of the Driver board and measure across:
Pins 44 & 43
Printhead Heater
40
S
Pins 35 & 36
Printhead
Thermistor
3k
S
hot
100k
S
cold
Power Supply Check
Power supply voltages can be checked on the Power Supply board or
on the cable that goes to the Driver Board (Figure 7-2). Always turn
system off before disconnecting any internal cables.
M5 VDC & +12 VDC referenced to COM.
Measure across both legs when measuring AC voltage.
Measure b150 and –150 for the high voltage DC.
J4 of DRIVER PCB
PIN 1
+150 VDC
PIN 2
-150 VDC
PIN 3
NOT CONNECTED
PIN 4
+12 VDC
PIN 5
+5 VDC
PIN 6
COMMON
PIN 7
36VAC
PIN 8
36VAC RET
Service
7-17
Summary of Contents for 6100
Page 8: ...This page intentionally left blank...
Page 18: ...2 8 Application Design This page intentionally left blank...
Page 21: ...Dimensions Controller Application Design 2 11...
Page 22: ...Integrated Printhead Wax System 2 12 Application Design...
Page 55: ...Command Definitions 5 21...
Page 56: ...5 22 Command Definitions This page intentionally left blank...
Page 70: ...6 14 Installation Setup Figure 6 6...
Page 87: ...7 8 Service Figure 7 1...
Page 89: ...7 10 Service Figure 7 2...
Page 95: ...7 16 Service Figure 7 3...
Page 97: ...7 18 Service This page intentionally left blank...
Page 115: ...8 18 Removal Replacement Procedures Figure 8 7...
Page 125: ...8 28 Removal Replacement Procedures This page intentionally left blank...