Driver Board Indicators
Service
7-9
LED
FUNCTION
TYPICAL STATE
HEAD OK
Indicates that Printhead is
connected
Lit if Printhead is
connected.
WAX OUT
Indicate WAX LOW
condition
Off until WAX LOW
condition is sensed.
HEAD AT
Indicates when Printhead is
at temp
Lite after Printhead reaches
temp. Should remain steady.
HEAD HTR
Indicates that Printhead
heating element is active
Lit while Printhead is
heating. Cycles on & off to
maintain temp.
TANK AT
Indicates that wax tank is
connected and heating
circuit is active
Lit after wax in tank
reaches temp. Should
remain steady.
TANK HTR
Indicates when wax hose
reaches temp
Lit while tank is heating.
Cycles on & off to maintain
temp.
HOSE AT
Indicates when wax hose
reaches temp
Lit after in hose reaches
temp. Should remain steady.
HOSE HTR
Indicates when wax hose
heating circuit is active
Lit while wax hose is
heating. Will go off when
wax in hose reaches temp.
Cycles on & off to maintain
temp.
HV OK
Indicates High Voltage on
Driver PCB
Lit if high voltage is OK.
Table 7-2
Summary of Contents for 6100
Page 8: ...This page intentionally left blank...
Page 18: ...2 8 Application Design This page intentionally left blank...
Page 21: ...Dimensions Controller Application Design 2 11...
Page 22: ...Integrated Printhead Wax System 2 12 Application Design...
Page 55: ...Command Definitions 5 21...
Page 56: ...5 22 Command Definitions This page intentionally left blank...
Page 70: ...6 14 Installation Setup Figure 6 6...
Page 87: ...7 8 Service Figure 7 1...
Page 89: ...7 10 Service Figure 7 2...
Page 95: ...7 16 Service Figure 7 3...
Page 97: ...7 18 Service This page intentionally left blank...
Page 115: ...8 18 Removal Replacement Procedures Figure 8 7...
Page 125: ...8 28 Removal Replacement Procedures This page intentionally left blank...