Backup Battery (Ni-Cad)
Some components on PCB’s are static sensitive. It is recommended
that static discharge precautions be observed when working in and
around the FoxJet controller and when handling FoxJet printed
circuit boards.
Rechargeable Ni-Cad batteries were installed on all CPU PCB’s
manufactured before November 1997. CPU PCB’s manufactured
after November 1997 will have lithium batteries.
Removal
1. Turn system power off.
2. Remove CPU PCB.
3. Unsolder three pins to BT1 on CPU PCB.
FoxJet cannot be held responsible for damage to boards occurring
from poor soldering techniques or faulty soldering equipment. Any
soldering on PCB’s performed outside of FoxJet’s Repair Facility will
void any and all warranties.
4. Carefully clean solder from holes.
Installation
1. Inspect battery for corrosion.
2. Position battery on board and solder in place.
3. Re-install CPU PCB and apply system power.
4. Measure battery voltage. Voltage should be 3.4 – 4.0 VDC.
Battery will recharge as long as power is applied to system.
8-8
Removal/Replacement Procedures
Summary of Contents for 6100
Page 8: ...This page intentionally left blank...
Page 18: ...2 8 Application Design This page intentionally left blank...
Page 21: ...Dimensions Controller Application Design 2 11...
Page 22: ...Integrated Printhead Wax System 2 12 Application Design...
Page 55: ...Command Definitions 5 21...
Page 56: ...5 22 Command Definitions This page intentionally left blank...
Page 70: ...6 14 Installation Setup Figure 6 6...
Page 87: ...7 8 Service Figure 7 1...
Page 89: ...7 10 Service Figure 7 2...
Page 95: ...7 16 Service Figure 7 3...
Page 97: ...7 18 Service This page intentionally left blank...
Page 115: ...8 18 Removal Replacement Procedures Figure 8 7...
Page 125: ...8 28 Removal Replacement Procedures This page intentionally left blank...