Network
Setup
Series 6 systems can be configured together into a printer network,
controlled by a stand-alone PC with SystemMaster installed.
SystemMaster can control up to 32 printer systems using RS485
serial communication. RS-485 is a communication protocol utilizing
two balanced signals referenced to each other, rather than
referenced to signal ground as in 4 wire RS-232 communication.
PC Configuration
When setting up an RS-485 communication port or card on PC, the
interface card should must be configured for the correct
communications port and interrupt request line. Alternatively, a
converter that converts RS232 to RS485 can be installed.
COM1 is typically used for the mouse. COM2 or COM3 should be
used for the FoxJet printer network. Be sure that no IRQ conflicts
exist. For further information, consult your MIS department.
COM PORT
PORT ADDRESS
IRQ#
COM1
03F8
4
COM2
02F8
3
COM3
03E8
11
COM4
02E8
12
Your PC setup may vary
The port must also be programmed for parity bits, data bits, stop bit,
and the baud rate of the interface card.
Installation & Setup
6-21
Figure 6-9
Summary of Contents for 6100
Page 8: ...This page intentionally left blank...
Page 18: ...2 8 Application Design This page intentionally left blank...
Page 21: ...Dimensions Controller Application Design 2 11...
Page 22: ...Integrated Printhead Wax System 2 12 Application Design...
Page 55: ...Command Definitions 5 21...
Page 56: ...5 22 Command Definitions This page intentionally left blank...
Page 70: ...6 14 Installation Setup Figure 6 6...
Page 87: ...7 8 Service Figure 7 1...
Page 89: ...7 10 Service Figure 7 2...
Page 95: ...7 16 Service Figure 7 3...
Page 97: ...7 18 Service This page intentionally left blank...
Page 115: ...8 18 Removal Replacement Procedures Figure 8 7...
Page 125: ...8 28 Removal Replacement Procedures This page intentionally left blank...