5.1.1 Attach 24 V uprights
Assembly
1. Undo the clamping plates of the hanger adapter ap-
prox. 50 mm with Allen key SW5.
2. In addition, the hanging adapter should be in the
retracted position. For this purpose, loosen the two
lateral SW4 clamping screws (1).
50 mm
SW4
1
Fig. 52: Upright axis assembly preparation
3. Mount one axis, consisting of two uprights and a lon-
gitudinal connector set, to the floor in a lying position.
4. Slide the longitudinal connector tubes onto the pins
and rotate them by 45° using the assembly tool.
NOTE
Tubes must be positioned properly
45°
Fig. 53: Frame assembly
Mounting to ceiling rail
5. Place the frame under the Multi-Lane rail and slide
the screw adapter upward up to the rail.
NOTE
Attention must be paid to laterally guiding the
cable out without it getting caught in the case of
electrified uprights. (For attachment of the power
supply, see Section 4.8)
Fig. 54: Positioning under Multi-Lane
6. After final positioning, tighten the screw adapter with
10 Nm.
7. Fix the screw adapter using the lateral SW4 screws (1).
SW4
1
F
=
10 Nm
Fig. 55: Firmly clamping