10
Multi-Lane
4/2022 (EN)
Fixing and visual check
SW19
SW15
SW16
2
1
Fig. 13: Securing with open-end spanners and visual check
WARNING
Risk of injury from goods or merchandise supports
falling down.
>
Please ensure that the threaded rod and the
screw have been screwed in enough.
Visual inspection: Threaded rod (Item 1, not sup-
plied) and screw (Item 2) must be visible!
3.3.3 Ceiling hanger
WARNING
>
The suspension point (attachment means) must
be able to bear at least 9.2 kN (design value).
>
Load from merchandise supports and merchan-
dise 150 kg/m or 80 kg per hanger adapter.
>
Each Multi-Lane profile is joined to one another
via a connector.
>
The Multi-Lane profile length is a maximum of
3000 mm
>
Each Multi-Lane profile is attached to the ceiling
using at least two suspension elements.
90˚
SW6
20Nm
Fig. 14: Fitting the profile to the ceiling hanger
NOTE
If the slot nuts are not lined up correctly, they
may not work properly.
>
Check visually and try by hand.
Alignment
172 - 272 mm
Fig. 15: Aligning the ceiling hangers
Fixing and securing
1
SW6
Bit Würth AW25
40Nm
Fig. 16: Fixing and securing
Screw in the securing screw (self-tapping screw) with a cord-
less screwdriver! Cover the screw with the cap (Fig. 16/1).
3.3.4 Connection of ceiling rails
Fixing overlapping ceiling rails
Fig. 17: Overlapping ceiling rails
NOTE
If the slot nuts are not lined up correctly, they
may not work properly.
>
Check visually and try by hand.