16
A100K10652
IP DECT 6000 System Installation & Configuration Guide
As the Server 6000 uses the DECT interface to synchronize on, one
base station is configured as the Sync Master. It is recommended to
place the Sync Master in the middle of the building or on the deck that is
mid-way between the decks of a ship.
)
It is recommended to make a site plan. Every base station must be numbered with
Radio ID, Primary sync Radio ID, and Secondary sync Radio ID.
3.2.2.1 Sync Chain With One Sync Master (Primary Sync
Ways)
Figure 2 Synchronization Chain
-The synchronization chain must always overlap with the base
station to sync on.
-No. 0 is the Sync Master (can be numbered 0 to 255).
-Other radio units are connected to the Sync Master through the
synchronization chain.
-
If one of the radio units in the synchronization chain is not working,
then all radio units behind are also not working.
Figure 3 Synchronization Chain Layout without Secondary Sync Ways
●
No. 0
is the Sync Master (can be numbered 0 to 255).
●
Green line
: Shows the primary sync ways.
●
Brown line
: Only handover overlap is needed.