10
A100K10652
IP DECT 6000 System Installation & Configuration Guide
required, it is necessary to either conduct a site survey or base the
deployment plan on the deployment guidelines.
2.4 Repeater
The repeater can be used to extend the coverage area in a wireless
radio synchronization solution, where it serves as a receiver and
transmitter in relaying radio signals. Depending on the repeater type,
it can be mounted either on the wall or on the ceiling. The wireless
repeater is used in areas with limited voice traffic, where cabling is
difficult. The repeater does not increase the number of traffic channels,
but increases the coverage area established with the base station. Up to
three repeaters can be placed in cascade formation directing coverage in
a certain direction. If the radio environment is difficult, one should avoid
installing repeaters.
Each base station can support up to 6 repeaters.
2.4.1 Programming Software
The application software for programming the repeater and software
downloads to the repeater is called ServiceTool.
)
ServiceTool is not used for adjusting the Rough/Office Handset.
The ServiceTool software is available as a download from the
STENTOFON AlphaWiki website.
2.5 Handset
The handset is a lightweight, ergonomically designed wireless unit that
includes an LCD display and keypad.
2.5.1 Handover
Handover refers to the ability to move between the coverage areas
of different radio units on the same system while talking, without
interruptions in the conversation.
2.6 Administrative Computer
An administrative computer is required for configuration and
maintenance of the Server 6000 and base station. This computer may
be temporarily connected directly to the device or to the network. A
dedicated computer is not required.
2.7 Requirements for the IP DECT 6000 System
This section provides information about the environmental, electrical,
and software requirements for the IP DECT 6000 System.
2.7.1 IP DECT Server 6000
2.7.1.1 Environmental Requirements
The installation area must be:
● clean, free of traffic and excess dust, dry, and well ventilated
●
within the temperature range of 10°C/50°F and 40°C/104°F