between 20% and 80% non-condensing relative humidity
)
The installation area must be of sufficient height from the floor to prevent water
damage.
2.7.1.2 Electrical Requirements
The following electrical requirements must be met:
●
Power consumption: 8V/500 mA
●
Typical power consumption: 5W per unit
●
The supplied power for the AC adaptor power supply must be 110 to
240 ac nominal, 50/60 Hz.
2.7.2 Base Stations and Repeaters
2.7.2.1 Environmental Requirements
●
Avoid installing base stations and repeaters on large concrete or
marble columns because they affect radio coverage. If possible,
place the base station a minimum of one meter/3.3 feet from these
types of columns.
●
Avoid installing a base station or repeater with the antenna housing
near metal objects. Be careful not to damage existing wiring or
panels.
-
On ships, the radiating cable solution is used instead.
● If possible, keep the base station and repeater away from steel
constructions.
-
On ships, the radiating cable solution is used instead.
●
Only position base stations and repeaters where the signal is
needed.
● The installation area must be clean, free of traffic and excess dust,
dry, and well ventilated.
●
The installation area must be within the temperature range of
10°C/50°F and 40°C/104°F.
●
The installation area must be between 20% and 80% non-
condensing relative humidity.
●
The minimum distance between two base stations varies depending
on the material and construction of buildings, but there must always
be synchronization chains and radio coverage overlap between the
two base stations or handover between radio units.
●
The time it takes a person to cross the common coverage area (of at
least 2 base stations) must be 10 seconds or more, as the handset
needs time to scan for an alternative base station.
2.7.2.2 Electrical Requirements for Base Station
The following electrical requirements must be met:
●
The base station operates on standard twisted pair Ethernet cable -
e.g. minimum Cat.5e - to prevent disturbances from other equipment.
●
Maximum power supply consumption is 3.0W (IEEE 802.3af class 1
device).
●
The maximum average radiated output power for the antenna is
10mW – peak radiation is 250 mW (over a time period of 0.4 ms)
EIRP/channel.