19
IP DECT 6000 System Installation & Configuration Guide
A100K10652
3.2.2.3 Sync Chain With and Without Secondary Sync Ways
Figure 8 Sync Chain With and Without Secondary Sync Ways
-No. 0 is the Sync Master (may be numbered 0 to 255).
-No. 10 and No. 20: Primary and secondary sync on No. 0.
-
No. 11, No. 12, and No. 13: Only primary sync.
-No. 14 and No. 15: Primary sync and secondary sync.
-
No. 21, No. 22, and No. 23: Only primary sync.
-No. 25: Primary sync on No. 24 and secondary sync on No. 15.
-No. 11 and No. 21: Only handover overlap (Marked in
green
).
Figure 9 Synchronization Chain With Repeaters
-No. 0 is the Sync Master (may be numbered 0 to 255).
-No. 10 and No. 20: Primary and secondary sync on No. 0.
-
No. 74, No. 138, and No. 202: Repeaters - no secondary sync
possible.
-No. 14 and No. 15: Primary sync and secondary sync on repeater.
-
No. 84, No. 148, and No. 212: Repeaters - no secondary sync
possible.
-No. 24 and No. 25: Primary sync and secondary sync.
-No. 74 and No. 84: Only handover overlap (Marked in
green
).