Appropriate RF safety/installation information
The product is intended to be installed by authorized personal. The product
shall be installed in accordance with FCC rules.
RF Exposure Statement
The EUT is considered as a mobile device according to OET Bulletin
65, Edition 97-01. Therefore distance to human body of min. 20 cm is
determined.
The internal/external antennas used for this mobile transmitter must provide
a separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
WARNING
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures. The above warning is inserted for regulatory
reasons. If any customer believes that they have an interference problem,
either because their product seems to cause interference or suffers
from interference, they should contact their distributor immediately. The
distributor will assist with a remedy for any problems.
Safety WARNING!
Only qualified service personnel may install this equipment. The
instructions in this manual are intended for use by qualified service
personnel only.
Only qualified persons should service the system.
The installation and service of this hardware is to be performed only by
service personnel having appropriate training and experience necessary to
be aware of hazards to which they are exposed in performing a task and of
measures to minimize the danger to themselves or other persons.
Electrical shock hazards from the telecommunication network and AC
mains are possible with this equipment. To minimize risk to service
personnel and users, the system must be connected to an outlet with a
third-wire Earth.
Service personnel must be alert to the possibility of high leakage currents
becoming available on metal system surfaces during power line fault
events near network lines. These leakage currents normally safely flow
to Protective Earth via the power cord. Therefore, it is mandatory that
connection to an earthed outlet is performed first and removed last when
!