70
2.
Route cables
B
and
F
through the
entry in the control panel and plug in
strain relief fittings.
3.
Secure cover
A
.
4.
Push the plug of connecting lead
F
(LV lead
< 42 V
) onto the
13-pin
plug-
in strip
X9
.
5.
Push the plugs of the connecting
cable
B
(control cable
230 V~
) onto
the
7-pin
plug-in strip
X2
and
15-pin
plug-in strip
X1
.
6.
Affix the individual cores of connect-
ing cable
B
(control cable
230 V~
)
to terminal
X14.6
for the PE connec-
tion.
7.
Secure connecting cables
B
and
F
with 4 cable ties
E
to bracket
C
.
8.
Bundle all cores of connecting cable
F
close to plug
D
using cable ties.
This ensures that if a fault occurs, for
example when detaching a wire, the
wires cannot drift into the adjacent
voltage area.
Installation sequence
Electrical connections in the control panel
(cont.)
5692 875 GB
Summary of Contents for Vitocal 300 AWO-M-AC 301.A
Page 5: ...5 Certificates Declaration of conformity 148 Keyword index 149 Index Index cont 5692 875 GB...
Page 47: ...47 Installation sequence Removing the transport brackets cont 5692 875 GB Installation...
Page 52: ...52 3x 3x 3x 3x 9 8 Installation sequence Fitting the outer panels cont 5692 875 GB...
Page 53: ...53 3x 10 3x 2x 11 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Page 104: ...104 Fitting the front panel 1 2 2 Installation sequence Closing the heat pump cont 5692 875 GB...
Page 128: ...128 051 052 008 066 038 063 064 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB...