81
Plug
sYA
Terminals
Function
Explanation
211.3
r
1.
Instantaneous heating
water heater control,
stage 1
Connection values:
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site (see installation instruc-
tions for instantaneous heating water
heater and control module).
211.4
M
r
Type AWCI-M-AC 301.A
:
3-way diverter valve for
"Central heating/DHW heat-
ing"
Type AWO-M-AC 301.A
:
Circulation pump for cylin-
der heating
Connection values:
■ Output: 130 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Type AWCI-M-AC 301.A
:
Connected at the factory.
Type AWO-M-AC 301.A
:
Connect on site.
211.5
NC/AC
3-way diverter valves for
heating water buffer cylinder
bypass in cooling mode
Connection values:
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site; terminate 3-way
diverter valves parallel to each other.
Installation sequence
Electrical connections in the heat pump control…
(cont.)
5692 875 GB
Installation
Summary of Contents for Vitocal 300 AWO-M-AC 301.A
Page 5: ...5 Certificates Declaration of conformity 148 Keyword index 149 Index Index cont 5692 875 GB...
Page 47: ...47 Installation sequence Removing the transport brackets cont 5692 875 GB Installation...
Page 52: ...52 3x 3x 3x 3x 9 8 Installation sequence Fitting the outer panels cont 5692 875 GB...
Page 53: ...53 3x 10 3x 2x 11 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Page 104: ...104 Fitting the front panel 1 2 2 Installation sequence Closing the heat pump cont 5692 875 GB...
Page 128: ...128 051 052 008 066 038 063 064 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB...