60
C
Heating water flow
D
Heating water return/DHW cylinder
return
Route condensate drain hose
B
out of
the heat pump and
connect via a siphon (backup level at
least 60 mm) to the on-site drain outlet.
Technical guide
Type AWO-M-AC 301.A
D
A
B
C
1.
3.
2.
1.
Cut suitable entries in sealing mat
B
for hydraulic pipes
A
,
C
and
condensate drain
D
.
2.
Push heating water return/DHW cyl-
inder return
C
onto the connector
and secure with open-ended pipe
clip.
3.
Push heating water flow/DHW cylin-
der flow
A
onto the connector and
secure with open-ended pipe clip.
Installation sequence
Connecting the heating circuits and condensate…
(cont.)
5692 875 GB