29
Pos.
Designation
Heating water buffer cylinder
zP
Heating water buffer cylinder
zQ
Buffer temperature sensor
zW
System flow temperature sensor
Heating/cooling circuit with mixer M2/HC2
uP
Underfloor heating circuit with directly controlled mixer motor
uQ
Vitotrol 200A remote control
uE
Flow temperature sensor
uR
Temperature limiter to limit the maximum temperature of underfloor heating
systems
■ as immersion thermostat or
■ as contact thermostat
uZ
Heating circuit pump
uU
Mixer motor in 3-way mixer
Active cooling function (AC) via heating/cooling circuit M2/HC2
iE
Contact humidistat (on site)
iU
3-way diverter valve for "heating/cooling" in the secondary circuit return
iI
3-way diverter valve for "heating/cooling" in the secondary circuit flow
Heating circuit without mixer A1/HC1
oP
Radiator heating circuit
oQ
Vitotrol 200A remote control
oZ
Heating circuit pump
Heating circuit with mixer M3/HC3
q-P
Radiator heating circuit controlled via KM BUS of heat pump control unit
q-Q
Vitotrol 200A remote control
q-E
Flow temperature sensor
q-T
Extension kit for 1 heating circuit with mixer
q-Z
Heating circuit pump
q-U
Mixer motor in 3-way mixer
Electrical installation scheme
For an overview of the electrical connec-
tions and more information on the PCBs,
see from page 63 and the separate
service instructions for the
Vitotronic 200 heat pump control unit.
For information regarding the power sup-
ply, see page 97.
Preparing for installation
System example 1, ID: 4605093_1006_01
(cont.)
5692 875 GB
Installation
Summary of Contents for Vitocal 300 AWO-M-AC 301.A
Page 5: ...5 Certificates Declaration of conformity 148 Keyword index 149 Index Index cont 5692 875 GB...
Page 47: ...47 Installation sequence Removing the transport brackets cont 5692 875 GB Installation...
Page 52: ...52 3x 3x 3x 3x 9 8 Installation sequence Fitting the outer panels cont 5692 875 GB...
Page 53: ...53 3x 10 3x 2x 11 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Page 104: ...104 Fitting the front panel 1 2 2 Installation sequence Closing the heat pump cont 5692 875 GB...
Page 128: ...128 051 052 008 066 038 063 064 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB...