87
Central fault message
223.1
L1
230 V~, 0.5 A
N
223.2
A
A
Terminals on extension PCB
Plug
sXF
Terminals
Function
Explanation
224.4
r
2.
Control of instantaneous
heating water heater,
stage 2
Connection values:
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site (see installation instruc-
tions for instantaneous heating water
heater and control module).
224.6
M
■ Cylinder primary pump
(DHW side)
■ 2-way shut-off valve
Connect cylinder primary pump and 2-
way shut-off valve in parallel.
Connection values:
■ Output: 130 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site.
224.7
Circulation pump for DHW
reheating
or
control of the immersion
heater (for connection, see
the following diagram)
Connection values:
■ Output: 100 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site.
Installation sequence
Electrical connections in the heat pump control…
(cont.)
5692 875 GB
Installation
Summary of Contents for Vitocal 300 AWO-M-AC 301.A
Page 5: ...5 Certificates Declaration of conformity 148 Keyword index 149 Index Index cont 5692 875 GB...
Page 47: ...47 Installation sequence Removing the transport brackets cont 5692 875 GB Installation...
Page 52: ...52 3x 3x 3x 3x 9 8 Installation sequence Fitting the outer panels cont 5692 875 GB...
Page 53: ...53 3x 10 3x 2x 11 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Page 104: ...104 Fitting the front panel 1 2 2 Installation sequence Closing the heat pump cont 5692 875 GB...
Page 128: ...128 051 052 008 066 038 063 064 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB...