background image

1

Summary of Contents for Heaters

Page 1: ...1 ...

Page 2: ...erly installed 6 As with any appliance close supervision is necessary when used by children 7 Do not operate this water heater if it has a damaged cord or plug if it is not working properly or if it has been damaged or dropped 8 This water heater should be serviced only by qualified service personnel Contact a service facility for examination repair or adjustment 9 Failure to service the anode rod...

Page 3: ...ons it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the open faucet at this time C 0 8 E DIMENSIONS FOR P10...

Page 4: ...any circumstances Closed Periodic discharge of the temperature and pressure relief valve or failure of the element system gasket may be due to thermal expansion in a closed water supply system The water utility thermal supply meter may contain a check valve backflow preventer or water pressure reducing expansion valve which will create a closed water system During the heating cycle of the water he...

Page 5: ...power fillthe tank and system with water and check for leaks To be testing certain that all the air is out of the water system open the hot water faucets on your fixtures until constant water flows from them otherwise damage to the element may occur To start the heating cycle A first make sure tank is full Otherwise the heating element may be damaged B move red on off switch letter F Fig 3 4 to th...

Page 6: ...ally an indication of a spent anode rod If rusty water is present examine anode rod immediately Rapid degradation of the anode rod less than 1 year may indicate the presence of galvanic corrosion due to stray direct current In this case it may be necessary to add a grounding strap from the Ariston tank to the copper plumbing 1 Unplug the power and drain the heater see previous section 2 Remove the...

Page 7: ...witch light has come on 4 If light does not come on check that the blue reset button B Fig 3 5 is pushed in follow steps from previous section 5 If the indicator light works properly but temperature does not get hot at tap test for a plumbing crossover shut off cold supply to heater and open hot water tap There should be no water flowing Any continued flow indicates a crossover which will effect t...

Page 8: ...8 ...

Page 9: ... if a The water heater or any of its component parts has been subject to misuse alteration neglect or accident or b The water heater has not been installed in accor dance with the applicable local plumbing and or building code s and or regulation s or c The water heater has not been installed in accor dance with the printed manufacturer s instructions or d The water heater is not continuously supp...

Page 10: ...10 COMMON SENSE HEAT HOT WATER TECHNOLOGY Controlled Energy Corp 340 Mad River Park Waitsfield VT 05673 800 642 3111 802 496 4436 Fax 802 496 6924 www controlledenergy com ...

Page 11: ...ING ELEMENT BRACKET 7 HEATING ELEMENT RETAINING NUT 8 TEMPERATURE DIAL 9 COVER 10 SCREW 11 THERMOSTAT WIRE HARNESS 12 GROUND SCREW 13 GROUND SCREW LOCK WASHER 14 THERMOSTAT 691551 15 POWER CORD BRACKET 16 HANGING BRACKET 570341 17 POWER CORD INTERIOR COMPONENTS DIAGRAM ARISTON P10 P15 ...

Reviews: