Function Parameter Table VD560 Series Inverter User Manual
- 58 -
F6-11
DO5 Closing
Delay
0.0s~3600.0s
0.0s
○
F6-12
HDO1 Output
Function
Selection
0
○
F6-13
AO1 Output
Function
Selection
0
○
F6-14
AO2 Output
Function
Selection
0: Running frequency
1: Set frequency
2: Output current (2 times of rated motor
current)
3: Output torque
4: Output power
5: Output voltage
6: PULSE input (100% corresponding
100.0kHz)
7: AI1
8: AI2
9: AI3 (expansion card)
10: Length
11: Count value
12: Communication setting
13: Motor rotate speed
14: Output current (when≤55kW, 100.0%
corresponding 100.00A; when>55kW,
100.0% corresponding 1000.00A)
15: Output voltage (100.0%
corresponding 1000.00A)
16: Encoder feedback frequency
1
○
F6-15
HDO1 Output
Max Frequency
0.01kHz~100.00kHz
50.00kHz
○
F6-16
AO1 Output
Voltage Lower
Limit
0.00V~10.00V
0.00V
○
F6-17
Corresponding
Setting Value of
AO1 Output
Voltage Lower
Limit
0.0%~F6-19
0.0%
○
F6-18
AO1 Output
Voltage Upper
Limit
0.00V~10.00V
10.00V
○
F6-19
Corresponding
Setting Value of
AO1 Output
Voltage Upper
Limit
F6-17~100.0%
100.0%
○
F6-20
AO1 Output
Filter Time
0.00s~10.00s
0.00s
○
F6-21
AO2 Output
Voltage Lower
Limit
0.00V~10.00V
0.00V
○