Function Parameter Table VD560 Series Inverter User Manual
- 60 -
Function
1: STOP/RES key stop function all valid
in any operation mode
F7-02
LED Running
Display
Parameter 1
0000~0xFFFF
Bit00: Running frequency (Hz)
Bit01: Set frequency (Hz)
Bit02: Bus voltage (V light on)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI input state
Bit08: DO output state
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit11: AI3 (expansion card) (V)
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
BIT15: PID setting
0x001F
○
F7-03
LED Running
Display
Parameter 2
0000~0xFFFF
Bit00: PID feedback
Bit01: PLC stage
Bit02: PULSE input frequency (kHz)
Bit03: Running frequency 2 (Hz)
Bit04: Set torque (0.%)
Bit05: Voltage before AI1 correction (V)
Bit06: Voltage before AI2 correction (V)
Bit07: Voltage before AI3 correction (V)
Bit08: Line speed
Bit09: Current power on time (Hour)
Bit10: Current running time (Min)
Bit11: PULSE input frequency (Hz)
Bit12: Communication setting value
Bit13: Encoder feedback speed (Hz)
Bit14: Main frequency X display (Hz)
Bit15: Auxiliary frequency Y display (Hz)
0x0000
○
F7-04
LED Display
Stop Parameter
0000~0x3FFF
Bit00: Set frequency (Hz)
Bit01: Bus voltage (V)
Bit02: DI input state
Bit03: DO output state
Bit04: AI1 voltage (V)
Bit05: AI2 voltage (V)
0x0033
○