VD560 Series Inverter User Manual Function Parameter Table
- 51 -
F4-01
Torque Boost
Mode Selection
0: Automatic torque boost
1: Manual torque boost
0
◎
F4-02
Manual Torque
Boost
0.0%~30.0%
Model
dependent
○
F4-03
Manual Torque
Boost Cutoff
Frequency
0.00Hz~max frequency
50.00Hz
◎
F4-04
MS VF
Frequency Point
1
0.00Hz~F4-05
0.00Hz
◎
F4-05
MS VF Voltage
Point 1
0.0%~100.0%
0.0%
◎
F4-06
MS VF
Frequency Point
2
F4-04~F4-07
0.00Hz
◎
F4-07
MS VF Voltage
Point 2
0.0%~100.0%
0.0%
◎
F4-08
MS VF
Frequency Point
3
F4-05~Rated motor frequency (F2-04)
0.00Hz
◎
F4-09
MS VF Voltage
Point 3
0.0%~100.0%
0.0%
◎
F4-10
VF Slip
Compensation
Gain
0.0%~200.0%
20.0%
◎
F4-11
VF Oscillation
Suppression
Mode
0: Mode 0
1: Mode 1
0
◎
F4-12
VF Oscillation
Suppression
Gain
0~100
Model
dependent
○
F4-13
Maximum
Overshoot of VF
Oscillation
Suppression
0~1000
200
○
F4-14
The Separation
of VF Voltage
Source
0: Digital setting (F4-15)
1: AI1
2: AI2
3: AI3 (expansion card)
4: PULSE setting
5: MS instruction
6: Simple PLC
7: PID
8: Communication given
Remark: 100% corresponding rated
0
○